Indicator
Best when an operator needs a local weight display, tare functions, calibration access and simple outputs.
Indicators, transmitters and signal conditioning products for accurate load cell measurement and system integration.
Features Basic panel mount weighing indicator Compact size : 96x47x107 (depth)mm 4 digit 0.8 inch LED display Auto zero tracking and manual zero Set points hi low control alarm Selectable filter Programmable buzzer
Features Connect all kinds of loadcells from single point, shear beam, compression, tension etc in a variety of environments. Capable of up to 4 x 350ohm loadcells in parallel Output 4-20ma or 0-10v - selectable terminal connection Adjustable Power supply needed : 24v dc Din Rail mount To be mounted in a panel for environmental.
Features Weighing Program New bright graphic display (4.5’’) and capacitive touchpad Indexed menu system Simple connection (Solder-free) 1600 Hz measurement / 800 Hz data output rate USB reporting / update / backup / calibration backup Esit gResolver superior multi-frequency vibration filtering technology Easy calibration (mV,.
Features Connect all kinds of loadcells from single point, shear beam, compression, tension etc in a variety of environments. Capable of up to 4 x 350ohm loadcells in parallel Output 4-20ma or 0-10v - selectable terminal connection Adjustable Power supply needed : 24v dc IP65 enclosure 0-40 degree operation
Features Bluetooth communication Multiple mounting options included: panel, din rail and glad protection 5-digit LED weight display Dust and humidity-proof keypad Taring, zeroing, function keys Zeroing within the entire measurement range Gain adjustment for loadcell output RS232 / RS485 serail output Internal 2 relay outputs.
Features Wifi communication Multiple mounting options included: panel, din rail and glad protection 5-digit LED weight display Dust and humidity-proof keypad Taring, zeroing, function keys Zeroing within the entire measurement range Gain adjustment for loadcell output RS232 / RS485 serail output Internal 2 relay outputs Analog.
Features Three-way galvanic isolation Internal power supply for current output eliminates need for external power supply Zero setting up to 50% of full range Error indicator in case of over voltage Relay state indication 0-20 mA Current and 10V Voltage output
This symbolizes the level of Ingress Protection for electronic materials, in accordance with the IEC 529, DIN 40050, BS 5490 and NF C 20-010 standards
0 = Non protected
1 = Protected against solid foreign objects of 50mm diameter and greater
2 = Protected against foreign objects of 12.5mm diameter and greater
3 = Protected against solid foreign objects of 2.5mm diameter and greater
4 = Protected against solid foreign objects of 1.0 mm diameter and greater
5 = Dust protected
6 = Dust tight
0 = Not protected
1 = Protected against vertically falling water drops
2 = Protected against falling water drops as the enclosure is tilted 15 degrees
3 = Protected against spraying water
4 = Protected against splashing water
5 = Protected against water jetting
6 = Protected against powerful water jetting
7 = Protected against temporary immersion
8 = Protected against continuous immersion
Loadcell or accessory models starting with the following letters refer to the material they are made from:
H = Alloy Steel / L = Aluminium / B = Stainless Steel
The majority of the products manufactured by Zemic and therefore the weighing prodcuts and loadcell models Richter Scale offer for sale are genuine OIML approved products.
The International Organization of Legal Metrology (OIML) is an intergovernmental treaty organization which develops model regulations, standards and related documents for use by legal metrology authorities and industry, provides mutual recognition systems which reduce trade barriers and costs in a global market, represents the interests of the legal metrology community within international organizations and forums concerned with metrology, standardization, testing, certification and accreditation, promotes and facilitates the exchange of knowledge and competencies within the legal metrology community worldwide, cooperates with other metrology bodies to raise awareness of the contribution that a sound legal metrology infrastructure can make to a modern economy.of the economy and ruining our reputation by selling cheap products that don't last. Buying an industrial scale that will stand up to the rigours of the local market and operators requires careful and fully informed research.
We are an NRCS and SANAS accredited Verification body and Repair body under the Legal Metrology Act and Legal Metrology Regulations. Our products are type approved for trade use / prescribed purpose and thus carry the NRCS stamp of quality and excellence, giving you the confidence that you will get a product that meets a standard of quality and reliability which is traceable to international metrology and quality standards.
A load cell is the heart of any scale. Inferior metals, combined with un-tested and unstable strain gauges within these load cells mean that these cannot perform consistently in various conditions, temperatures or even during simple repeatability testing by the untrained operator! Look for a trusted brand with quality materials and a supplier like us with direct factory backing and guarantees. Beware of copies and imitations. If it’s not sourced from Richter Scale there is a chance it could be a copy or model made for entry level domestic use.
First check if the scale/weighing system is for trade/prescribed purpose or not? If they are then 99/100 times you will have to replace with the same make and model.
Non trade applications - if the size and hole patterns fit then you are free to substitute your current load cell with a ZEMIC LOAD CELL.
Analogue load cells :
*Sends mV via the signal lines to the instrument which has an Analogue to Digital convertor.
*Easy to substitute and replace with other manufacturers.
*Cheaper.
Digital load cells :
*These have an Analogue to Digital convertor attached to the body or inside the load cell. It then sends RS422/485 to the indicator.
*More expensive
*Less/no compatibility with other manufacturers.
*Protocol locked.
The strain gauges and body/element material of the same brand load cells between these 2 technologies remain the same.
It is only on the digital conversion side where they differ in technology.
You can either click on the download spec sheet button located on the individual loadcell page or you can visit our downloads page
Areas or sites with potentially hazardous or explosive environments require weighing equipment which has EX ratings. Many of our Alloy and Stainless steel loadcells are available in an EX version. These should be paired with EX rated junction boxes and EX rated instrumentation.
Dusty and/or wet/corrosive applications call for greater protection against dust and moisture. IP ratings vary from IP65, IP66, IP67, IP68, IP69
These levels and numbers indicate the level of exposure and/or submersion in water and exposure to dust which the load cell can withstand before ingress (leakage) inside the load cells.
Instrumentation converts load cell signals into useful weight readings, analogue outputs, digital communication or control actions.
Best when an operator needs a local weight display, tare functions, calibration access and simple outputs.
Best for PLC or automation systems that need 4-20mA, 0-10V, RS485 or other process signals.
Best for batching, filling, dosing, alarms or process control where the weighing system must trigger actions.
Confirm excitation voltage, mV/V input range, filtering, resolution, communication protocol and enclosure rating.
Use shielded cable, correct earthing, stable power and separate load cell wiring from high-voltage motor cables.
Instrumentation should be selected with the load cell capacity, number of cells, environment and user workflow in mind.
Use a transmitter when the weight signal must feed a PLC, SCADA or automation system.
Yes, when the cells are summed correctly and the instrument supports the combined signal.